What was found
AT C CHECK; MAIN CARGO COMPARTMENT FLOOR ATTACH ANGLE BROKEN 1/2 INCH, STA 1726.00 BLD. REMOVED AFFECTED AREA IAW SRM 53-2-0 FIG 1B, CLEANED,TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, FABRICATED AND INSTALLED FILLER AND "U" ANGLE IAW SRM 53-2-0, FIG 1B. REF: N/R 0951.