What was found
AT C CHECK; AFT CARGO COMPT. FLOOR SUPPORT CRACKED AT STA 1340 L-35R. PERFORMED STOP DRILL IAW SRM 53-2-0 PG 2E/2F, CLEANED,TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, FABRICATED AND INSTALLED DOUBLER IAW SRM 53-2-0 PAGE 2E/2F. REF: N/R 2119.