What was found
AT C CHECK; NR 9 TRANSFERENCE FLOOR LWR SKIN CRACKED AND UPPER SKIN BROKEN. PERFROMED STOP DRILL IAW SRM 53-2-3, FIG 5, CLEANED,TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, FABRICATED AND INSTALLED DOUBLERS IAW SRM 53-2-3 FIG 5. REF: N/R 0854.