What was found
AT C CK; AFT CARGO COMPARTMENT FLOOR SUPPORT CRACKED 1 INCH, 1440 BETWEEN LONGERON 34 TO 36 RT. PERFORMED STOP DRILL IAW SRM 53-2-3, FIG 5, FABRICATED AND INSTALLED DOUBLER IAW SRM 53-2-3, FIG 5. REF: N/R 2018.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT C CK; AFT CARGO COMPARTMENT FLOOR SUPPORT CRACKED 1 INCH, 1440 BETWEEN LONGERON 34 TO 36 RT. PERFORMED STOP DRILL IAW SRM 53-2-3, FIG 5, FABRICATED AND INSTALLED DOUBLER IAW SRM 53-2-3, FIG 5. REF: N/R 2018.