What was found
AT C CHECK; MAIN CARGO COMPARTMENT FLOOR LWR SIDE ATTACH ANGLE CRACKED 1/2 INCH BETWEEN STA 1746 TO STA 1766 BLO. REMOVED DAMAGED ANGLE IAW SRM 53-2-0, FIG 1B, CLEANED,TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, FABRICATED AND INSTALLED ANGLE IAW SRM 53-2-0 FIG 1B. REF: N/R 0953.