What was found
AT C-CHECK, RT ELEVATOR LINK BRACE HOUSING PLATE CRACKED .5 INCH AT XE 149.000. REMOVED DAMAGED PLATE IAW SRM 51-1-21, PG 1, CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, FABRICATED AND INSTALLED NEW PLATE IAW SRM 51-1-21, PG 1.