What was found
MAIN CARGO COMPT FLOOR SUPPORT ANGLE 3 INCH CRACK AT STA 1700.000 LBL 22 IN. STOP DRILLED PER SRM 53-2-0. FABRICATED ANGLE DOUBLER PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8B. INSTALLED DOUBLER PER SRM 53-2-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CARGO COMPT FLOOR SUPPORT ANGLE 3 INCH CRACK AT STA 1700.000 LBL 22 IN. STOP DRILLED PER SRM 53-2-0. FABRICATED ANGLE DOUBLER PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8B. INSTALLED DOUBLER PER SRM 53-2-0.