What was found
RIGHT WING L/E INTERNAL PART RIB CRACKED 1 INCH AT XFS 743.000 (518 ACCESS PANEL). STOP DRILLED PER SRM 57-2-5. FABRICATED DOUBLER PER SRM 57-2-5. CLEANED, TREATED AND PRIMED PER SRM 51-1-8B. INSTALLED DOUBLER PER SRM 57-2-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RIGHT WING L/E INTERNAL PART RIB CRACKED 1 INCH AT XFS 743.000 (518 ACCESS PANEL). STOP DRILLED PER SRM 57-2-5. FABRICATED DOUBLER PER SRM 57-2-5. CLEANED, TREATED AND PRIMED PER SRM 51-1-8B. INSTALLED DOUBLER PER SRM 57-2-5.