As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
1) AT FL 250 LEADING EDGE AMBER LIGHT ILLUMINATED.S/O FLAP INDICATOR SHOW LEFT NR 2 KLUEGER FLAP EXTENDED (A/C FLYS NORMAL ) DESCENDED TO FL 200 AND SLOWED TO 230 KTS.RECYCLED FLAPS, ALL INDICATIONS WERE NORMAL. 2) INSPECTED & CLEANED CONNECTOR ON NR 2 KRUEGER FLAP SWITCH. NO DEFECTS NOTED. PERFORMED OPERATIONAL TEST OF LEADING EDGE FLAPS & CHECKS GOOD AT THIS TIME IAW B-727 M/M 27-82-0. STATUS: CLOSED