What was found
1) NR 3 FIRE WARNING LOOP GIVES SHORT CIRCUIT LIGHT IN FIRE POSITION INTERMITTANTLY. 2) DEFERRED NR 3 ENG B LOOP FIRE DETECTION IAW MEL 26-2-3 DMI 7170, SPEC PROC C/W, PLACARD INSTALLED. 3) REMOVED & REPLACED FAN,FIRE DETECTOR LOOP. OPS CK GOOD AS PER MM 26-10-0. CLEARED DMI 7170. AC OK FOR SERVICE. STATUS: CLOSED