What was found
MAIN CARGO COMPT-CTR FLOORING PANEL 1A UPPER SKIN BROKEN.CUT OUT DAMAGED AREA PER SRM 53-2-3,FABRICATED FILLER AND DOUBLER PER SRM 53-2-3.CLEANED ,TREATED AND PRIMED PER SRM 51-1-8B,INSTALLED FILLER AND DOUBLER PER SRM 53-2-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CARGO COMPT-CTR FLOORING PANEL 1A UPPER SKIN BROKEN.CUT OUT DAMAGED AREA PER SRM 53-2-3,FABRICATED FILLER AND DOUBLER PER SRM 53-2-3.CLEANED ,TREATED AND PRIMED PER SRM 51-1-8B,INSTALLED FILLER AND DOUBLER PER SRM 53-2-3.