What was found
MAIN CARGO COMPT FLOOR TRACK 2L SHOWS CORROSION AROUND FASTNERS STA 940-970. CUT OUT DAMAGED FLOOR TRACK 2 L/H PER SRM 53-2-3. FABRICATED SPLICE PER SRM 52-2-3. CLEANED,TREATED AND PRIMED PER SRM 51-1-8B. INSTALLED TRACK AND SPLICE PER SRM 53-2-3.