What was found
1) DURING CRUISE FLIGHT SSC (SINGLE STROKE CHIME) AND MWP "LOOPS" LIGHT ILLUMINATED. FIRE DETECTOR LOOP PANEL CHECKED AND LOOPS A & B TESTED NORMAL. MWP LOOPS & SSC CONTINUED INTERMITTENT. 2) TROUBLESHOT AND FOUND MASTER WARNING CONTROLLER DEFECTIVE. REMOVED AND REPLACED MASTER WARNING CONTROLLER PER MM REF 33-15-11. OK TO CONTINUE.