What was found
1) #2 ENG SYSTEM "B" FIRE LOOP WILL NOT TEST.2) DEFERRED PER DHL MEL 26-2-3 CONTROL #9112 S.P 26-2 COMPILED WITH. R.LEVY 8616.3) REF W/O # 600005727 T/S #2 ENG B-LOOP FIRE DETREF DMI 9112 #2 ENG FIRE LOOP WONT TEST4) REMOVED AND INSPECTED ALL FIRE LOOP CONNECTIONS ON NO.2 ENG. REINSTALLED ALL CONNECTORS. FIRE LOOPS TEST GOOD IAW MM 26-10-0. THIS CLOSES W/O 600005727