What was found
APU FIRE WARNING WILL NOT TEST. TROUBLESHOT SYSTEM, VERIFIED INTEGRITY OF THE SENSOR/RESPONDER, TEST SWITCH, OPERATING POWER UNIT, AND WIRING UP TO SENSOR/RESPONDER PER B727 MM 26-15-00. PLACED ITEM ON DEFERRAL, DMI NR 11766, PER MEL 26-11-1 C.