What was found
FUESLAGE FRAME AT STA 540 IS DENTED BETWEEN STR 16R-17R. CUT OUT DENTED AREA AND FABRICATED REPAIR PER SRM 51-40-3. TREATED AND PRIMED REPAIR PARTS AND INSTALLED PER SRM 51-40-1 FIG 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.