What was found
AFT ACCY COMPT FORMER FLANGE CRACKED 2.000, STA 640.000. REMOVED FASTENERS IAW SRM 51-1-21 PG 1, SRM 51-1-20D PG 21. TRIMMED OUT CRACKED FORMER IAW SRM 53-2-0 PG 11. FABRICATED NEW FORMER AND SPLICE PLATE IAW SRM 53-2-0 PG 11. CLEANED, TREATED AND PRIMED IAW SRM 51-1-8B. INSTALLED NEW FORMER AND SPLICE PLATE WITH NEW FASTENERS IAW SRM 53-2-0 PG 11, SRM 51-1-20D PG 9, SRM 51-1-21 PG 1.