What was found
FWD ACCY COMPT FRAME CRACKED 1.000, STA 55.000, L-24L (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW SRM 53-2-0 FIG 2. REMOVED FASTENERS IAW SRM 51-1-20D PG 21. TRIMMED OUT DAMAGED FRAME IAW SRM 53-2-0 FIG 2. FABRICATED FRAME SEGMENT AND SPLICE ANGLE (02 EA) IAW SRM 53-2-0 FIG 2. PERFORMED HEAT TREATMENT IAW SRM 51-1-1 PG 1, 13, 17 SRM 51-1-4 PG 1-3. CLEANED, TREATED AND PRIMED IAW SRM 51-1-8B. INSTALLED NEW FRAME SEGMENT (WITH NEW FASTENERS) AND SPLICE ANGLES IAW SRM 53-2-0 FIG 2, SRM 51-1-20D PG 9.