What was found
FWD PASSENGER DOOR JAMB UPPER FWD CORNER INTERIM REPAIR, STA 25.000 L-9L TO L-10L (MAJOR REPAIR). PERFORMED MAJOR REPAIR, SERVICE REWORK DWG SRO 8530021, DWG 5750776. REMOVED INTERIM REPAIR. TRIMMED OUT AFFECTED AREA IAW SRM 53-2-0 FIG 15, SERVICE REWORK DWG SRO 8530021, DWG 5750776. FABRICATED DOUBLER, TRIPLER, FILLER IAW SRM 53-2-0 FIG 15, SERVICE REWORK DWG SRO 8530021, DWG 7570776. CLEANED, TREATED AND PRIMED AREA AND FILLER AND DOUBLER AND TRIPLER IAW SRM 51-1-8B. APPLIED (PRC) SEALANT TO FAYING SURFACES IAW SRM 51-1-11 PG 9. INSTALLED FILLER AND DOUBLER AND TRIPLER WITH NEW FASTENERS IAW SRM 53-2-0 FIG 15, SRM 51-1-20D PG 9, SRM 51-3-0 PG 1.