What was found
EXTERNAL FUSELAGE FWD PASSENGER DOOR JAMB AFT LWR CORNER CRACKED 0.750 STA 55.000, L20 - L21L (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW SRM 53-2-0 FIG 15, SERVICE REWORK DWG SRO8530021, DWG 5750776. REMOVED FASTENERS IAW SRM 51-1-21 PG 1. TRIMMED OUT DAMAGED AREA IAW SRM 53-2-0 FIG 15, SERVICE REWORK DWG SRO8530021, DWG 5750776. FABRICATED FILLER DOUBLER AND TRIPLER IAW SRM 53-2-0 FIG 15, SERVICE REWORK DWG SRO8530021, DWG 5750776. CLEANED, TREATED AND PRIMED FILLER AND DOUBLER AND TRIPLER AND AREA IAW SRM 51-1-8B. APPLIED PRC SEALANT ON FAYING SURFACES IAW SRM 51-1-11 PG 9. INSTALLED FILLER AND DOUBLER AND TRIPLER WITH NEW FASTENERS.