What was found
RIGHT WING EXTENDED L/E INBD VANE FWD OUTER PLATING ELONGATED HOLES AROUND STA XS 247.000 (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW ED EDU38-3 AND DWG U38-R03. REMOVED FASTENERS, TRIMMED OUT THE DAMAGED SKIN AREA. PERFORMED NDT INSPECTION. CLEANED, TREATED AND PRIMED AREA , FABRICATED AN EXTERNAL REPAIR DOUBLER, A FILLER AND INTERNAL DOUBLER. CLEANED, TREATED AND PRIMED THE EXTERNAL REPAIR DOUBLER INTERIOR SURFACE, FILLER AND INTERNAL DOUBLER. APPLIED PRC SEALANT ON FAYING SURFACES IAW SRM 51-1-11 PG 9. INSTALLED REPAIR PARTS ON EXTENDED L/E INBD VANE (RT WING STA XS 247.000) USING NEW FASTENERS IAW ED EDU38-3 AND DWG U38-R03, SRM 51-1-21 PG 1 AND SRM 51-3-0 PG 1.