What was found
RIGHT OUTBD STUB WING RIB HOLES ELONGATED STA XOLDO 67.750 (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW SRM 57-1-0 PG 1, ATM 201846, DWG 9753297. REMOVED DAMAGED RIB IAW SRM 51-3-0 PG 1, SRM 51-1-21 PG 1, SRM 51-1-20D PG 21. FABRICATED RIB IAW ATM 201846, DWG 9753297. HEAT TREATED IAW SRM 51-1-1 PG 13, 21 SRM 51-1-4 PG 1. CLEANED, TREATED AND PRIMED IAW SRM 51-1-8B. INSTALLED NEW RIB IAW SRM 51-1-20D PG 9 SRM 51-1-21 PG 1, SRM 51-3-0 PG 1.