What was found
LEFT WING CTR L/E FORMER CRACKED 0.500 AT STA XS 461.372. REMOVED FASTENERS IAW SRM 51-1-21 PG 1. PERFORMED STOP HOLE ON CRACK END IAW SRM 57-2-0 PG 9, 10. FABRICATED ANGLE DOUBLER IAW SRM 57-2-0 PG 9, 10. CLEANED, TREATED AND PRIMED IAW SRM 51-1-8B. INSTALLED ANGLE DOUBLER WITH NEW FASTENERS ON LEFT WING CTR L/E FORMER, STA XS 461.372 IAW SRM 57-2-0 PG 9, 10 SRM 51-1-20D PG 9 SRM 51-1-21 PG 1.