What was found
FWD CARGO COMPT FITTING ATTACHING CUSP EXTRUSION TO FLOORBEAM WITH TWO CRACKS OF 3.000 AND 1.000 AT STA 340.000 (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW SRM 53-1-0 PG 1. REMOVED CRACK FITTING IAW SRM 51-1-20D PG 21. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B. INSTALLED NEW FITTING IAW SRM 51-1-20D PG 9 SRM 51-3-0 PG 1.