What was found
RIGHT WING CTR L/R FORMER 1.000 CRACKED, STA XFS 304.000 (LWR SECTION). PERFORMED STOP HOLE ON CRACK END (0.250) IAW SRM 57-2-0 PG 9-10. FABRICATED ANGLE DOUBLER IAW SRM 57-2-0 PG 9-10. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B. INSTALLED ANGLE DOUBLER IAW SRM 57-2-0 PG 9-10, IAW SRM 51-1-21 PG 1, SRM 51-1-20D PG 9.