What was found
LEFT OUTER WING INBD L/E FORMER CRACKED 0.500, STA XFS 610.000. REMOVED FASTENERS IAW SRM 51-1-21 PG 1. PERFORMED STOP HOLE ON CRACK END IAW SRM 57-2-0 PG 9-10. FABRICATED ANGLE DOUBLER IAW SRM 57-2-0 PG 9-10. CLEANED, TREATED AND PRIMED IAW SRM 51-1-8B. INSTALLED ANGLE DOUBLER WITH NEW FASTENERS ON LEFT OUTER WING INBD L/E XFS 610.000 IAW SRM 51-1-21 PG 1, SRM 51-1-20D PG 9, SRM 57-2-0 PG 9-10.