What was found
RIGHT WING CTR L/E FORMER 1.000 CRACKED, STA XFS.410.250 (UPPER SECTION). REMOVED FASTENERS IAW SRM 51-1-21 PG 1, 2. PERFORMED STOP HOLE ON CRACK END IAW SRM 57-2-0 PG 9-10. FABRICATED ANGLE DOUBLERS 2 EA IAW SRM 57-2-0 PG 9-10. CLEANED, TREATED AND PRIMED AREA AND ANGLE DOUBLERS IAW SRM 51-1-8B. INSTALLED ANGLE DOUBLERS WITH NEW FASTENERS IAW SRM 57-2-0 PG 9-10 SRM 51-1-20D PG 9, SRM 51-1-21 PG 1, 2.