What was found
RIGHT WING CTR L/E FORMER CRACKED 1.000, STA XFS 404.000. REMOVED FASTENERS IAW SRM 51-1-21 PG 1, 2. PERFORMED STOP HOLE ON CRACK END IAW SRM 57-2-0 PG 9-10. FABRICATED ANGLE DOUBLERS (02 EA) IAW SRM 57-2-0 PG 9-10. CLEANED, TREATED AND PRIMED AREA AND ANGLE DOUBLERS IAW SRM 51-1-8B. INSTALLED ANGLE DOUBLERS WITH NEW FASTENERS IAW SRM 51-1-21 PG 1, 2 SRM 57-2-0 PG 9-10, SRM 51-1-20D PG 9.