What was found
FWD ACCY COMPT FRAME CRACKED 3.000 AT STA 55.000, L-25R (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW SRM 53-2-0 FIG 2. REMOVED FASTENERS IAW SRM 51-1-21 PG 1, SRM 51-1-20D PG 21. TRIMMED OUT CRACKED FRAME SEGMENT IAW SRM 53-2-0 FIG 2. FABRICATED FRAME SEGMENT AND SPLICES (02 EA) IAW SRM 53-2-0 FIG 2. PERFORMED HEAT TREATMENT IAW SRM 51-1-1 PG 17. CLEANED, TREATED AND PRIMED IAW SRM 51-1-8B. INSTALLED NEW FRAME SEGMENT AND SPLICES WITH NEW FASTENERS IAW SRM 53-2-0 FIG 2, SRM 51-1-2 PG 1, SRM 51-1-20D PG 9.