What was found
LEFT WING CTR L/E FORMER CRACKED 0.500 AT STA XS 442.185. REMOVED FASTENERS IAW SRM 51-1-21 PG 1. PERFORMED STOP HOLE ON CRACK END IAW SRM 57-2-0 PG 9-10. FABRICATED ANGLE DOUBLERS IAW SRM 57-2-0 PG 9-10 (2024-T3 0.032, 2024-T3 0.040). CLEANED, TREATED AND PRIMED IAW SRM 51-1-8B. INSTALLED NEW ANGLE DOUBLERS WITH NEW FASTENERS ON LEFT WING CTR L/E FORMER, STA XS 442.185 IAW SRM 57-2-0 PG 9-10, SRM 51-1-20D PG 9, SRM 51-1-21 PG 1.