What was found
AFTER LANDING DURING TAXI INTO RAMP NR 3 ENGINE HAD AN UNCOMMANDED SHUTDOWN. REPLACED MEC IAW M/M 73-21-10. PERFORMED RUN AND POWER ASSURANCE IAW JRH 13.3 AND M/M 71-00-00. OPS AND LEAK CHECKS SERVICEABLE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFTER LANDING DURING TAXI INTO RAMP NR 3 ENGINE HAD AN UNCOMMANDED SHUTDOWN. REPLACED MEC IAW M/M 73-21-10. PERFORMED RUN AND POWER ASSURANCE IAW JRH 13.3 AND M/M 71-00-00. OPS AND LEAK CHECKS SERVICEABLE.