As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
WHEN FLAPS SELECTED TO 2DEG INBD FLAP ASSYMETRIC PERFORMED ABNORMAL PROCEDURE ISOLATING INBD FLAP MOTOR CONTROL WHEN FLAP SELECTED 5 DEG ASSYMETRIC INBD FLAP LOWERED TO 5 DEG AND OUTBDS LOCKED OUT. ADJUSTED IND AND OUT FLAP XMITTERS AND CLEANED CONNECTORS, OPS CK GOOD IAW MM 27-52-13. OPS CK GOOD SEE ITEM 2 P FOR CORRECIVE ACTION, NO DEFECT NOTED IAW MM 27-52-13.