What was found
RT INBD FLAP UPPER EXTERNAL SKIN INTERIM REPAIR, STA XW 104.000-110.000 (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW SRM 57-1-0 PG.1, SRM 57-7-1 FIG. 1. REMOVED PLATING WITH EXISTING INTERIM REPAIR IAW SRM 51-1-21 PG.1. FABRICATED NEW PLATING (AL2024Y3 0.040) IAW SRM 57-7-1 FIG. 1 ITEM D. CLEANED, TREATED AND PRIMED NEW PLATING INTERNAL PART AND AREA IAW SRM 51-1-8B. APPLIED PRC SEALANT TO FAYING SURFACES IAW SRM 51-1-11 PG.9. INSTALLED NEW PLATING IAW SRM 51-1-21 PG.1, SRM 51-3-0 PG. 1. TORQUED IAW SRM 51-3-1.