As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
NR 2 MAIN TANK INTERIOR OUTBD FWD FITTING CRACKED STA XRS 74.869 S-61 (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW SRM 57-1-0 PG.1. REMOVED CRACKED FITTING IAW SRM 51-1-21 PG.1, SRM 51-1-20D PG. 21. CLEANED AND APPLIED TOP COATING MATERIAL TO AREA IAW SRM 51-1-12 PG. 7. APPLIED SEALANT TO FAYING SURFACE IAW SRM 51-1-12. INSTALLED NEW FITTING IAW SRM 51-1-20D PG. 9, SRM 51-1-23 (PLI WASHER) TORQUED IAW SRM 51-3-1. REFER TO NR. 030838 FOR LEAK CHECK.