What was found
MAIN CARGO COMPT FRAME INBOARD FLANGE (2EA) MISDRILLED HOLES AT STA 1260.00 L-10R (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW FAA FORM 8110-3 DATED 03-07-05, EO AST 050201 DATED 02-17-05. PERFORMED DETAIL VISUAL INSPECTION, NO CRACK FOUND. CLEANED, TREATED AND PRIMED MISDRILLED HOLES AREA IAW SRM 51-1-8B. REPAIRED DAMAGED AREA PLUGGING MISDRILLED HOLES WITH RIVETS (MS20470AD) IAW EO AST 050201, SRM 51-1-21 PG 1.