As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
NR 3 MAIN TANK FITTING 2" CRACK STA XRS 139.000 BETWEEN S-7 AND S-8. REMOVED CRACKED FITTING IAW SRM 51-1-20D. CLEANED, TREATED AND APPLIED TOP POLYURETHANE YELLOW COATING IAW SRM 51-1-12 PG 7-25. INSTALLED NEW FITTING IAW SRM 51-1-20D, SRM 51-3-1. REFER TO NR 047726 FOR LEAK CHECK.