What was found
RT INBD AFT FLAP CONTROL CABLE ACTUATOR ROD LOWER MOUNTING BRACKET LOOSE INSIDE FLAP, RWBL 101.0. ACCESS GAINED TO AFFECT REPAIR; CUT OUT AFT FLAP L/E SECTION, 8.5" BY 14" PER B727 SRM 57-40-4 FIG 17. FABRICATED 2 REPAIR SPLICES FROM 2024-T3, .050" BY 5.5" BY 14", AND .050" BY 5" BY 14", PO NR 9004042, PER B727 SRM 57-50-4 FIG 11. TREATED, PRIMED, AND INSTALLED REPAIR PARTS PER B727 SRM 51-10-2 AND 57-50-4 FIG 11.