What was found
RT OTBD SLOT VANE HAS A NON STANDARD REPAIR, STA XS 512.000 (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW FAA FORM 8110-3 DATED 01-31-07, DWG NR AC62-57-104 REV A DATED 01-31-07. REMOVED NON STANDARD REPAIR IAW SRM 51-1-21, SRM 51-3-0, SRM 51-1-20D. CUT OUT DAMAGED SECTION IAW DWG AC62-57-104 AND PERFORMED NDT INSPECTION IAW DC8 NDT SPM PART 06-10-01-001. NO CRACK OR CORROSION FOUND. ENCLOSED SMN FORM 242-2. FABRICATED (1EA) SPLICE DOUBLER (AL7075T6 0.071") INTERNAL DOUBLER (AL7075T6 0.050") AND 1 EA PLATING SEGMENT (AL7075T6 0.063") IAW DWG NR AC62-57-104. CLEANED, TREATED AND PRIMED AREA, SPLICE DOUBLER, INTERNAL DOUBLER AND PLATING SEGMENT INNER FACE IAW SRM 51-1-8B. APPLIED SEALANT TO FAYING SURFACE IAW