What was found
AFT ACCY COMPT SHOWS CORROSION AT STA 1660.000 L-24L (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW SRM 53-2-2 FIG 4A. REMOVED CORROSION IAW SRM 51-1-8 PG 17-18. FOUND OUT OF LIMITS IAW SRM 53-2-0 PG 2P. REMOVED FASTENERS IAW SRM 51-1-20D. CUT OUT DAMAGED SECTION AND FABRICATED NEW LONGERON SEGMENT (EXTRUSION P/N S2610338) IAW SRM 53-2-2 FIG 4A, SRM 53-4-1 FIG 44 SHEET 2 ITEM "C", SRM 51-2-0 FIG 50 SHEET 51 AND SPLICE (EXTRUSION P/N S2641454) IAW SRM 53-2-2 FIG 10 SHEET 4, TR NR 53-193 DATED 06-15-04, SRM 51-2-0 FIG 50 SHEET 62, SRM 53-2-2 FIG 10 SHEET 1, 3, TR NR 53-153 DATED 12-10-02. PERFORMED NDT INSPECTION IAW DC8 SRM 53-2-2 FIG 10 SHEET 4 NOTE 22. CLEANED, TREATED AND PRIMED AREA AND REPAIR PARTS IAW S