What was found
NR 4 MAIN TANK FITTING CRACKED STA XRS -255.000 S-51. REMOVED CRACKED FITTING IAW SRM 51-1-20D. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B. INSTALLED NEW FITTING IAW SRM 51-1-20D, SRM 51-3-1 (TORQUE). FOR FITTING FABRICATION SEE JC EC-00293-001 (WO 470).