What was found
RT WING T/E FITTING CRACKED AT STA XRS 421.000. REMOVED CRACKED FITTING IAW SRM 51-1-20D. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B. INSTALLED NEW FITTING IAW SRM 51-1-20D, SRM 51-3-1 (TORQUE).
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RT WING T/E FITTING CRACKED AT STA XRS 421.000. REMOVED CRACKED FITTING IAW SRM 51-1-20D. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B. INSTALLED NEW FITTING IAW SRM 51-1-20D, SRM 51-3-1 (TORQUE).