What was found
AT C-CHECK, RT MLG FWD PANEL SUPPORT ASSY HAS A STRUT WEB CRACK. STOP DRILLED .250 END OF CRACK AND FABRICATED REPAIR DOUBLER 4.0 X 2.0, INSTALLED PER SRM 53-2-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT C-CHECK, RT MLG FWD PANEL SUPPORT ASSY HAS A STRUT WEB CRACK. STOP DRILLED .250 END OF CRACK AND FABRICATED REPAIR DOUBLER 4.0 X 2.0, INSTALLED PER SRM 53-2-0.