What was found
AT C- CHECK, FWD CARGO COMPT AT STA 240L FLOOR PANEL BOTTOM PLATING 12 FROM OUTBD IS CRACKED. FABRICATED REPAIR, STOP DRILLED CRACK AND INSTALLED REPAIR PER SRM 53-2-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT C- CHECK, FWD CARGO COMPT AT STA 240L FLOOR PANEL BOTTOM PLATING 12 FROM OUTBD IS CRACKED. FABRICATED REPAIR, STOP DRILLED CRACK AND INSTALLED REPAIR PER SRM 53-2-3.