What was found
C-CHECK, LT WING, L/B HINGE, 2 INCH CRACK UNDER FLAP FITTING ATTCH POINT WING STA: XW 5.000. STOP DRILLED END CRACK .25 AT LT WING L/B FLAP L/B HINGE UNDER FLAP FITTING ATTACH POINT IAW DC-8 SRM 51-3-2 PG 1 PAR 1. FABRICATED ANGLE REPAIR 2024-T3 050. 6 X 3 IAW DC-8 SRM 51-1-4 PG 1 PAR 1. TREATED AND PRIMED PER DC-8 SRM 51-1-8 PAG 16,13 PAR 6 & 6F. INSTALLED REPAIR PER DC-8 SRM 51-1-21 PG 1 PAR 1.