What was found
C-CHECK, RT WING O/B L/E INTO THRU ACCESS PANEL 519C CRACKED RIBS TO UPPER END XFS 622 AND XFS 644 DOT 64131-64132. STOP DRILLED END CRACK AT RT WING O/B L/E RIBS STA XFS 641 & 622 IAW DC-8 SRM 57-2-0 PG 9 FIG 2. FABRICATED ANGLE REPAIR 2024 T3 050 .75 X 1.25 X 5 IAW DC-8 SRM 57-2-0 PG 10 FIG 2. TREATED & PRIMED PER DC-8 SRM 51-1-8 PG 16 & 13 PAR 6 & 6F. INSTALLED PER DC-8 SRM 51-1-21 PG 1 PAR 1.