What was found
C-CHECK, RT WING O/B L/E INT THRU ACCES PANEL 518B CRACKED RIBS AT THE UPPER END XFS 772; XFS 779 & XFS 785 DOT 64124-64125-64126. STOP DRILLED END CRACK AT RT WING O/B L/E RIBS STA XFS 772, XFS 779 & XFS 785 IAW DC-8 SRM 51-3-2 PG 1 PAR 1 & SRM 57-2-0 PG 9/10 FIG 2. FABRICATED ANGLE REPAIR 2024 T3 050 .75 X 1.25 X 6 IAW DC-8 SRM 57-2-0 PG 9 FIG 2. TREATED & PRIMED PER DC-8 SRM 51-1-8 PG 16 & 13 PAR 6 & 6F. INSTALLED ANGLE REPAIR PER DC-8 SRM 51-1-21 PG 1 PAR 1.