What was found
C-CHECK, RT WING O/B L/E INT THRU ACCESS PANEL 518A RIB CRACK AT UPPER END XFS 797 DOT 64123. STOP DRILLED END CRACK AT RT WING O/B L/E RIB STA XFS 797.000 IAW DC-8 SRM 57-2-0 PG 9 FIG 2. FABRICATED ANGLE REPAIR 2024 T3 .050 .75 X 1.25 X 5 IAW DC-8 SRM 57-2-0 PG 10 FIG 2. TREATED & PRIMED PER DC-8 SRM 51-1-8 PG 13 & 16 PAR 6 & 6F. INSTALLED PER DC-8 SRM 51-1-21 PG PAR 1.