What was found
C-CHECK, RT WING O/B L/E INT THRU ACCES PANEL 517B RIB CRACK AT UPPER END XFS 848 DOT 64118. STOP DRILLED END CRACK AT RT WING O/B L/E RIBS STA XFS 848 & IAW DC-8 SRM 57-2-0 PG 9 FIG 2. FABRICATED ANGLE REPAIR 2024 T3 050 .75 X 1.25 X 5 IAW DC-8 SRM 57-2-0 PG 10 FIG 2. TREATED AND PRIMED PER DC-8 SRM 51-1-8 PG 16 & 13 PAR 6 & 6F. INSTALLED PER DC8 SRM 51-1-21 PG 1 PAR 1.