What was found
AT C-CHECK, LT WING I/B FLAP UPPER WITH 3 DENTS, 2 IN CENTER AND 1 T/E AREA. CUT OUT DAMAGED AREA AND FABRICATED REPAIR DOUBLER 2 X 2 AND FABRICATED AND REPLACED T/E AREA 40 X 7.5 PER SRM 51-1-21A. N/R 934
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT C-CHECK, LT WING I/B FLAP UPPER WITH 3 DENTS, 2 IN CENTER AND 1 T/E AREA. CUT OUT DAMAGED AREA AND FABRICATED REPAIR DOUBLER 2 X 2 AND FABRICATED AND REPLACED T/E AREA 40 X 7.5 PER SRM 51-1-21A. N/R 934