What was found
AT C-CHECK, RT WHEEL WELL KEEL BEAM AT STA 880 THERE IS SPLICE CRACK 5 INCHES LONG. STOP DRILLED CRACKED AREAS. FABRICATED REPAIR ANGLES 7 X 2 X 3. INSTALLED PER SRM 51-1-20.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT C-CHECK, RT WHEEL WELL KEEL BEAM AT STA 880 THERE IS SPLICE CRACK 5 INCHES LONG. STOP DRILLED CRACKED AREAS. FABRICATED REPAIR ANGLES 7 X 2 X 3. INSTALLED PER SRM 51-1-20.